Devon & County
High Output Boiler Stoves
Instructions for Use, Installation & Servicing
For use in GB & IE (Great Britain & Republic of Ireland).
PM964 Issue 3 (January 2014)
IMPORTANT
THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY HOT DURING
OPERATION AND WILL RESULT IN SERIOUS INJURY AND BURNS IF TOUCHED. IT IS
THEREFORE RECOMMENDED THAT A FIREGUARD COMPLYING WITH BS 8423:2002 IS
USED IN THE PRESENCE OF YOUNG CHILDREN, THE ELDERLY OR INFIRM.
Do not attempt to burn rubbish in this appliance.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found on page 3 of these instructions should be completed by the Installer.
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Devon & County

Devon & CountyHigh Output Boiler StovesInstructions for Use, Installation & ServicingFor use in GB & IE (Great Britain & Republic of I

Page 2 - Contents

105.20 Control the temperature and hot water output using the Thermostatic Control.THERMOSTATThis appliance is designed to be controlled by the therm

Page 3

116.1 Remove the riddling mechanism from the appliance (see Pre-Installation, Section 5). To fit the Wood Burning Tray:6.2 Remove the log guard a

Page 4 - Getting Started

12All Fuels: — Insert the Riddling Tool into the socket, see Diagram 19.Rotate to operate19 — Rotate the Riddling Tool backward and forward 3 or 4

Page 5

13Care & Maintenance — Remove the cleaning plate from the back of the appliance and clear the debris. (see Pre-Installation Instructions, S

Page 6

1415. Seasonal Use15.1 Clean and service the appliance if not used during the warmer months, as detailed in the Maintenance and Servicing section.15.

Page 7

15Care & MaintenanceLeft Hand Double Door17.6 To replace the double door left hand door knob, unscrew the fixing on the back of the door.17.7 R

Page 8

16TroubleshootingSymptom Cause SolutionOPERATIONDifficulty starting the fire andkeeping it burning wellLow flue draught Consult your installerWet wood

Page 9

17TroubleshootingSymptom Cause SolutionTHE APPLIANCERapid creosote build-up in the chimney Wet wood (over 20% moisture)Use dry seasoned wood (less tha

Page 10 - User Instructions

18Description A B C D E F G H I J K (dia) Devon 50590 659 389 118 469 430 120 400 241 315 153 County 60632 772 446 125 507 508 126 530 246 343 153 Cou

Page 11 - Care & Maintenance

19Installation Checklist2. Essential InformationGENERALModel:Yeoman Devon 50Yeoman County 60Yeoman County 80Yeoman Devon 50Yeoman County 60Yeoman C

Page 12

2Covering the following models:YM-DEV-50HBMF2/ YM-COU-60HBMF2/ YM-COU-60HBW2/ YM-COU-80HBMF2/ YM-COU-80HBW2Yeoman - High Output Boiler StovesContentsA

Page 13

20Installation Checklist4. Minimum Dimensions - Hearth4.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm

Page 14

21Installation ChecklistFireplace: Minimum Clearances to the Rear Combustible MaterialsNon-Combustible MaterialsFloorHearthAE7BNon-Combustible Mater

Page 15

221. General1.1 To make the installation of the appliance easier it is best to remove the internal components before fitting into the builders openin

Page 16 - Troubleshooting

23Front supportBaffle In PlaceEnsure baffle sits on Secondary Air Chamber43.6 Remove and clean the baffle system to ensure the flue ways are clear of

Page 17

245. Removal of the Riddling Mechanism The riddling mechanism can be removed for cleaning to maintain good working condition. To remove the riddling

Page 18 - Installation Checklist

25Installation Instructions1. Installing the ApplianceEach installation is unique to the property so it is not possible to give details to suit every

Page 19

26Installation Instructions —Secure with self tapping screw —Seal the connecting joints with fire cement. Donotusea90˚elbowtomakethisconne

Page 20

273. Hot Water Cylinder3.1 The domestic hot water cylinder must be an indirect vented double feed type to meet national standards** and should have a

Page 21

28Installation InstructionsHigh Output Boilerinstalled to BS8303, ADJ and these installation instructionsHigh limit pipe thermostatto bring on circula

Page 22 - Pre-Installation Instructions

29Installation Instructions10. Fully Pumped System10.1 In many installations (especially new build) a fully pumped system is the best choice to give

Page 23

3Retailer appliance was purchased from:Name:Address:Telephone number:Essential information - MUST be completed:Date Installed:Model Description:Serial

Page 24

30Commissioning1. Commissioning1.1 To commission: — Replace the internal components. — Check the door alignment and catch operation, adjust if

Page 25 - Installation Instructions

31Certificate Of Compliance Upon completing the installation, the form below must be filled in by your installer to comply with the requirements of H

Page 26

32For a complete list of spare parts and accessories contact your Yeoman retailer or call 01392 4740111. Annual Service1.1 Before the start of the he

Page 27

333. Removing the Woodburning Tray (if fitted) To maintain safe use of the appliance the Woodburning tray should be removed and cleaned regularly .3.

Page 28

34Maintenance & Servicing5.3 Remove old rope and scrape old glue from locating groove.Rope seal 12x3mmRope seal 14mm35.4 Clean the locating groo

Page 29

35Maintenance & Servicing Lock the nut and catch stub tightly together to fix this position.To loosen To tighten6Use 2 x 17A/F ring spanners as s

Page 30 - Commissioning

36Technical AppendixLegal RequirementsBefore installation and/or use of this appliance please read these instructions carefully to ensure that all req

Page 31 - Certificate Of Compliance

37Technical Appendix - Flues2. Flue or Chimney2.1 The flue or chimney system must be in good condition. It must be inspected by a competent person a

Page 32 - Maintenance & Servicing

382. Ventilation2.1 Many older buildings are sufficiently ventilated by natural leakage of air to provide suitable air supply for an appliance of 5kW

Page 33

39Technical Appendix4. Fitting Appliances On A Boat4.1 If an appliance is to be fitted in a boat it must be done in accordance with the latest editio

Page 34

4Welcome Congratulations on purchasing your Yeoman Boiler, if installed correctly Yeoman hope it will give you many years of warmth and pleasure for

Page 35

40DEVON50&COUNTY60MULTI-FUELHIGHOUTPUTBOILERSCOUNTY 80 MULTI-FUEL HIGH OUTPUT BOILERBasic Spare PartsDue to continual technical improvemen

Page 36 - Technical Appendix

41Due to continual technical improvements please check online at www.yeomanstoves.co.uk for the most up to date parts lists.COUNTY 60 WOOD BURNING HIG

Page 37 - Technical Appendix - Flues

42Basic Spare PartsDue to continual technical improvements please check online at www.yeomanstoves.co.uk for the most up to date parts lists.DOORASSE

Page 38 - 2. Ventilation

431RIDDLING GRATE BAR2FIXED GRATE BAR3R/H INFILL4RIDDLING TOOL 5RIDDLING SOCKET 6ASHPAN TOOL7ASHPAN8RIDDLING BAR9BACK RIDDLING BAR10L/H INFILLRef. Des

Page 39

441STSERVICEDate of Service:...Next Service Due:...

Page 43

Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LFTel: (01392) 474011 Fax: (01392) 219932 E-mail: [email protected]

Page 44 - Service Records

5Getting StartedAIR CONTROLSTriple Air Systems Several Yeoman appliances have triple air systems providing cleaner burning, and greater efficiency an

Page 45

61.19 It is also recommended to fit a low limit thermostat on the centralheatingreturnsetat45˚C.Thisthermostatwillturnthepumpoffifther

Page 46

7User Instructions Poor quality timber: — Causes low combustion efficiency — Produces harmful condensation — Reduces effectiveness of the airwash

Page 47

8User InstructionsBase of Baffle8Log Guard —Close the door. Do not run with the door slightly open except for initial lighting as this could cause o

Page 48 - HETAS Approval

9User Instructions NOTE IF THE THERMOSTAT IS SET TO MAXIMUMTHEWATERLEAVINGTHEBOILERWILL BE APPROXIMATELY 85˚C.Control KnobSetting Indicator-+11