Yeoman YM-W9302HC Operations Instructions

Browse online or download Operations Instructions for Stoves Yeoman YM-W9302HC. Yeoman YM-W9302HC Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Exmoor/Exe/Devon/County
Free Standing Stove
Instructions for Use, Installation & Servicing
For use in GB & IE (Great Britain & Republic of Ireland).
PM943 Issue 1 (July 2013)
IMPORTANT
THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY HOT DURING
OPERATION AND WILL RESULT IN SERIOUS INJURY AND BURNS IF TOUCHED. IT IS
THEREFORE RECOMMENDED THAT A FIREGUARD COMPLYING WITH BS 8423:2002 IS
USED IN THE PRESENCE OF YOUNG CHILDREN, THE ELDERLY OR INFIRM.
Do not attempt to burn rubbish in this appliance.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found on page 3 of these instructions should be completed by the Installer.
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Exmoor/Exe/Devon/County

Exmoor/Exe/Devon/CountyFree Standing Stove Instructions for Use, Installation & ServicingFor use in GB & IE (Great Britain & Republic of I

Page 2 - Contents

10 — Remove the baffles and clear the debris (see Pre-Installation Instructions, Section 4).10.6 To refresh painted finishes a touch up spray is av

Page 3

11User Instructions15. Optional ExtrasSmoke Control Kit15.1 Some appliances can be modified to burn wood in a smoke control zone. For more details on

Page 4 - Getting Started

12TroubleshootingSymptom Cause SolutionOPERATIONDifficulty starting the fire andkeeping it burning wellLow flue draught Consult your installerWet wood

Page 5

13TroubleshootingSymptom Cause SolutionTHE APPLIANCERapid creosote build-up in the chimney Wet wood (over 20% moisture)Use dry seasoned wood (less tha

Page 6 - 4. Lighting the Appliance

14Installation ChecklistPlease NoteThis section is intended to give an overview of the product performance and essential information required for inst

Page 7

15Installation Checklist2. Essential InformationGENERALModel:Exmoor ExeDevon County ExmoorExeDevonCountyNominal Heat OutputWood kW 4.9 4.9 9 13Solid F

Page 8

16Installation Checklist3. Minimum Dimensions - Hearth3.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm

Page 9 - 10. General Cleaning

17Installation ChecklistFreestanding Installation5CBAA150150Non Combustible MaterialCombustible Materials4.3 It is essential for safety to ensure the

Page 10 - User Instructions

181. General1.1 To make the installation of the appliance easier it is best to remove the internal components before fitting into the builders openin

Page 11

19Pre-Installation Instructions4.4 The front lip of the Baffle should point downwards.Baffle Extension TubesSupport PinRear Lip34.5 Lift the Baffle

Page 12 - Troubleshooting

2Covering the following models:YM-EXM-W1/YM-EXM-MF1/YM-EXM-WLC1/YM-EXM-MFLC1/YM-EXE-W1/YM-EXE-W2/YM-EXE-WLC1/YM-EXE-WLC2/YM-EXE-MF1/YM-EXE-MF2/YM-EXE-

Page 13

201. Installing the ApplianceEach installation is unique to the property so it is not possible to give details to suit every setting. The installation

Page 14 - Installation Checklist

21Installation Instructions1.3 Rear flue pipe installationCapSelf Tapping ScrewSeal Collar with Fire CementTeeSize Part No.5" 45166" 46165

Page 15

22 Connect the Riddling Arm to the Operating Rod and secure with the 2 lock nuts. The nuts must sit above and below the Operating Rod, see Diagram 9

Page 16

23CommissioningCommissioning1.1 To commission: — Replace all internal components. — Check the door alignment and catch operation, adjust if re

Page 17

24Certificate Of Compliance Upon completing the installation, the form below must be filled in by your installer to comply with the requirements of H

Page 18 - Pre-Installation Instructions

25Maintenance & ServicingFor a complete list of spare parts and accessories contact your Yeoman retailer or call 01392 4740111. Annual Service1.1

Page 19

263. Fitting a new Door Glass To maintain safe use of the appliance damaged door glass must be replaced immediately. To do this:3.1 Remove the doo

Page 20 - Installation Instructions

274.4 Clean the locating groove with a clean, dry cloth to remove all old dust and debris.4.5 Squeeze a generous bead of fresh Stovax Thermic Seal g

Page 21

28LegCap Head ScrewsView Underneath Appliance5IMPORTANT: IT IS ESSENTIAL THAT THE BRACKET AND SCREWS ARE REPLACED ON COMPLETION OF THIS OPERATION IN

Page 22

29Maintenance & Servicing10 — Fit the fixing stubs on the canopy into the position previous occupied by the Top Plate studs. — Use the M8 washer

Page 23 - Commissioning

3Retailer appliance was purchased from:Name:Address:Telephone number:Essential information - MUST be completed:Date Installed:Model Description:Serial

Page 24 - Certificate Of Compliance

30Technical AppendixLegal RequirementsBefore installation and/or use of this appliance please read these instructions carefully to ensure that all req

Page 25 - Maintenance & Servicing

31Technical Appendix - Flues1. Flue or Chimney1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person a

Page 26

32Ventilation - Technical Appendix 2. Ventilation2.1 Many older buildings are sufficiently ventilated by natural leakage of air to provide suitable a

Page 27

334. Fitting Appliances On A Boat4.1 If an appliance is to be fitted in a boat it must be done in accordance with the latest edition of BS 8511 (Code

Page 28

34Basic Spare PartsTYPICAL WOOD APPLIANCETYPICAL MULTI-FUEL APPLIANCEDue to continual technical improvements please check online at www.yeoman-stoves.

Page 29

35RefNo.Description1 FLUE COLLAR2 TOP ASSEMBLY3 CANOPY ROPE4 BLANKING PLATE5 DATA PLATE MOUNT6 UPPER SIDE FIREBRICK7 RIDDLING KIT ASSEMBLY*8 TERITARY

Page 30 - Technical Appendix

36Basic Spare PartsEXE, DEVON, COUNTY DOUBLE DOORDue to continual technical improvements please check online at www.yeoman-stoves.co.uk for the most u

Page 31 - Technical Appendix - Flues

37Due to continual technical improvements please check online at www.yeoman-stoves.co.uk for the most up to date parts lists.RefNo.Description1 DOOR R

Page 32 - 2. Ventilation

381STSERVICEDate of Service:...Next Service Due:...

Page 34 - Basic Spare Parts

4Welcome Congratulations on purchasing your Yeoman Stove, if installed correctly Yeoman hope it will give you many years of warmth and pleasure for w

Page 35

Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LFTel: (01392) 474011 Fax: (01392) 219932 E-mail: [email protected]

Page 36

5Getting StartedAIRWASH & PRIMARY AIR CONTROLS1.13 Use the stub on the end of the tool or a gloved hand to operate air controls.Primary ControlOp

Page 37 - COUNTY MULTI-FUEL KIT

63. Recommended Fuels3.1 Wood Logs: Burn only seasoned timber with a moisture content of less than 20%. To ensure this allow cut wood to dry for 12

Page 38 - Service Records

7User Instructions4.6 Add larger pieces of wood. Do not use full sized logs at this stage, build up gradually in size. Too many logs may smother th

Page 39

8Multi-fuel Stove5.10 To burn wood and smokeless fuels a cast iron multi-fuel kit must be fitted. Allow the fire to become established before addin

Page 40 - A division of Stovax

9User Instructions/Care & Maintenance7.2 Multi-fuelVersions De-ash the appliance before filling with new fuel. Do not allow ash to build up on