Yeoman YM-CL5MF User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
23
7. CAST TOP
This appliance can be fitted with an optional cast top plate.
The type of plate will depend on whether the appliance is
installed with a top* or rear flue exit.
Top Flue Rear Flue
Yeoman CL3 YM-CL3CT YM-CL3CTR
Yeoman CL5 YM-CL5CT YM-CL5CTR
Yeoman CL8 YM-CL8CT YM-CL8CTR
* The cast top must be fitted at the same time as the flue
connection (see Installation Instructions, Sections 1 & 7).
7.1 The cast top plate has 4 silicon feet on the bottom to space
it off the top of the appliance by 6mm and allow the door
to open freely.
PR8756
Cast feet
7.2 Place the cast top plate feet down on top of the appliance.
—Ensure the cast top is flush with the front and sides of the
appliance.
—For the top flue version, position the cutout over the flue
ring.
PR8744
Line up edges
of cast top
plate with the
appliance
INSTALLATION INSTRUCTIONS
8. CO ALARMS
All open flued appliances can be affected by temporary
atmospheric conditions which may allow fumes to enter
the house. Building regulations require that whenever
a new or replacement fixed solid fuel or wood/biomass
appliance is installed in a dwelling a carbon monoxide
alarm must be fitted in the same room as the appliance.
Further guidance on the installation of the carbon
monoxide alarm is available in the latest edition of
BS EN50292 and from the alarm manufacturer's
instructions.
Provision of an alarm must not be considered a
substitute for either installing the appliance correctly
or ensuring regular servicing and maintenance of the
appliance and chimney system.
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 33 34

Comments to this Manuals

No comments